A 20 L/min gear pump pushing 160 bar of oil delivers 5.3 kW of hydraulic power. The motor bolted to the other side of the coupling is almost never 5.3 kW. On an industrial AC power pack it is usually a 7.5 kW frame. On a compact DC unit it can be a 2.2 kW motor pulling more than 110 A out of a 24 V battery. The gap between the number you calculate and the number on the nameplate is where most sizing arguments start, and it is why a lifting platform that works perfectly on the test bench can cook its motor after two months in a warehouse.
Hydraulic pump power is straightforward arithmetic once you know which pressure and which flow to feed into it. The hard part is that measured pressure, expected flow and assumed efficiency all move with oil temperature, valve losses and duty cycle. What follows puts the formula first, then works through the efficiency chain, real duty figures, motor and battery selection, and the heat that never makes it back into useful work.
The relationship between pressure, flow and power does not change with brand, size or country of manufacture:
Hydraulic power in kW = pressure in bar x flow in L/min / 600
The 600 is pure unit conversion. One bar is 100,000 pascals, one litre per minute is one sixtieth of a thousandth of a cubic metre per second, and the two constants collapse into 600. In imperial units the same relationship reads hydraulic power in hp = pressure in psi x flow in gpm / 1714, so a 2,000 psi, 10 gpm circuit lands at just under 11.7 hp.
A gauge on the pressure line during a full-load lift tells you what the pump is really working against. That figure is rarely the relief valve setting. Relief valves on power units are normally set 10 to 15 percent above the highest working pressure so that they stay quiet during normal operation, which means a machine running at 160 bar may have a valve cracking at 180 or 190 bar. Use the working pressure for continuous power calculations and reserve the valve setting for stall checks, hose rating and peak current on DC systems.
Displacement in cc per revolution multiplied by shaft speed in rpm and divided by 1000 gives theoretical flow in litres per minute. A 14 cc/rev gear pump turning at 1,450 rpm is theoretically good for 20.3 L/min. At 0.92 volumetric efficiency it actually delivers about 18.7 L/min under load. Cold oil at 5 degrees Celsius can cut delivery further while raising pressure losses, so a machine that is marginal in summer may simply not lift on a January morning.
Take the 160 bar, 20 L/min circuit again. Hydraulic power is 160 x 20 / 600 = 5.33 kW. Divide by an overall efficiency of 0.85 and the electrical input becomes 6.27 kW. The next standard IEC motor size is 7.5 kW. Note the roughly 40 percent gap between 5.33 kW and 7.5 kW: part of it is real loss, part of it is simply that motors come in discrete steps and nobody stocks a 6.3 kW frame.
Overall efficiency on a small hydraulic power unit is the product of several separate losses rather than one number. Understanding which one dominates tells you whether to change the pump, the motor or the circuit.
Compact power packs with gear pumps generally land between 0.80 and 0.88 combined. Larger fixed industrial systems running piston pumps at steady load can reach 0.88 to 0.92. Anything above 0.92 on a mobile DC unit is a claim worth testing before you design a battery pack around it.
| Hydraulic power (kW) | Input at 0.85 efficiency (kW) | Practical motor size (kW) |
|---|---|---|
| 1.7 | 2.0 | 2.2 |
| 3.3 | 3.9 | 4.0 |
| 5.3 | 6.3 | 7.5 |
| 8.0 | 9.4 | 11.0 |
| 10.7 | 12.6 | 15.0 |
| 16.8 | 19.8 | 22.0 |
Gear pumpsGear pumps are positive displacement pumps that rely on gear meshing to achieve liquid delivery. They can stably output high-pressure fluids, have a compact structure ...View Product →Sizing from a specification sheet alone is a common source of error, because the numbers on the drawing describe a new machine with warm oil and a clean filter. Measuring on the actual unit takes an hour and removes most of the guesswork. If you want the circuit behaviour behind these measurements, the note on the working principle of a hydraulic system walks through it step by step.
Required flow in L/min = piston area in square centimetres x speed in metres per minute / 10. Piston area for a bore of D millimetres is 3.1416 x D x D / 4, expressed in square centimetres. Force at a given pressure is area in square centimetres multiplied by pressure in bar and divided by 10, which gives newtons.
| Bore (mm) | Piston area (cm2) | Force at 160 bar (kN) | Flow for 6 m/min (L/min) |
|---|---|---|---|
| 40 | 12.6 | 20.1 | 7.5 |
| 50 | 19.6 | 31.4 | 11.8 |
| 63 | 31.2 | 49.9 | 18.7 |
| 80 | 50.3 | 80.4 | 30.2 |
| 100 | 78.5 | 125.7 | 47.1 |
Power rises linearly with both pressure and flow, which surprises people who expect a gentle curve. Halve the flow and you halve the power. Add 40 bar without touching the pump and you add 25 percent to the electrical bill and to the heat load. The table below uses round numbers that appear on real equipment labels.
| Pressure (bar) | Flow (L/min) | Hydraulic power (kW) | Input at 0.85 (kW) |
|---|---|---|---|
| 100 | 10 | 1.67 | 1.96 |
| 100 | 20 | 3.33 | 3.92 |
| 160 | 40 | 10.67 | 12.55 |
| 200 | 63 | 21.00 | 24.71 |
| 250 | 80 | 33.33 | 39.22 |
A practical note on the last row: 39.2 kW of input does not map onto a stock 37 kW motor safely once ambient temperature and altitude are considered. The sensible choice is 45 kW, or a change of circuit to bring the pressure down. Compacting a machine by raising pressure is the most expensive way to save space.
Hydraulic power is the same whether the shaft is turned by a mains motor or a battery. What changes is the electrical side, and on DC systems it changes dramatically.
A 7.5 kW four-pole motor on a 400 V three-phase supply draws roughly 14.5 A at full load. Starting current can be six to eight times that, so a power unit on a weak supply may need star-delta starting or a soft starter even though the running current looks modest. Single-phase supplies are practically limited to about 2.2 kW before starting current and voltage drop become a problem for the rest of the installation.
AC double acting power unitThis hydraulic power unit is specially designed for a double-acting oil cylinder system, which is integrated by a high-pressure gear pump, an AC motor, a central valve...View Product →
On DC, current is the constraint. A 2.2 kW motor on a 24 V system with 0.85 motor efficiency and 0.95 controller efficiency pulls 2,200 divided by 24 x 0.85 x 0.95, which is about 114 A. Move the same motor to 48 V and the current halves to roughly 57 A, which is why reach trucks and aerial platforms run higher voltages. Cable cross-section, fuse rating and connector type all follow from that peak current, not from the average.
DC double acting power unitThis DC double acting power unit is an integrated hydraulic system designed for various equipment that requires efficient hydraulic drive. It is suitable for double-ac...View Product →
Duty cycle decides whether the battery can actually deliver it. A typical warehouse lift runs a 20 L/min pump at 160 bar for 8 seconds of lift, 6 seconds of lower, then sits idle for three minutes. Peak current is high, average current is a small fraction of it, and a modest battery survives comfortably. A tail lift on a delivery route with fifteen stops an hour has a very different profile, and here average current and heat generation both matter.
Every watt of loss ends up in the oil. At 0.85 overall efficiency, a 7.5 kW motor feeding a power unit turns about 1.1 kW into heat that has to leave the reservoir, the hoses or a cooler. A compact tank of 10 litres cannot shed that continuously, which is why the same power pack that performs perfectly in intermittent use will climb past 70 degrees Celsius in a test rig that runs it non-stop.
Duty cycle also changes the answer to the original question. A 5.33 kW hydraulic demand that lasts four seconds every two minutes does not need a 7.5 kW motor if the thermal time constant of the motor frame covers the interval. In practice most suppliers still specify the larger frame, because the price difference is small and a stalled motor on a cold morning is expensive.
Most of the failures we see in the field trace back to one of a small number of decisions made early in the design.
A supplier can size a power unit accurately in a day if the enquiry contains the right six items. Without them, the response is a guess with a part number attached.
With those six answers, hydraulic pump power becomes a calculation rather than an opinion, and the resulting motor, pump displacement and tank size all follow from the same set of numbers.
Power in kilowatts equals pressure in bar multiplied by flow in litres per minute, divided by 600. In imperial units, horsepower equals psi multiplied by gallons per minute divided by 1714. The result is the hydraulic power delivered into the oil, not the electrical power drawn from the supply.
Two reasons. First, real efficiency sits between 0.80 and 0.88 on a compact power pack, so input power is roughly 15 to 25 percent above hydraulic power. Second, motors come in fixed sizes, so a 6.3 kW demand becomes a 7.5 kW frame. Add a service factor for hot ambient conditions and the gap widens further.
Hydraulic power is 5.33 kW. Allowing 0.85 overall efficiency, the electrical input is 6.27 kW, and the practical motor choice is 7.5 kW on an AC supply. On a 24 V DC system the same duty needs about 114 A at the motor terminals under load.
It changes the power required to do the same job. Cold oil is more viscous, so pressure losses through valves and lines rise and the pump may deliver less flow at a given speed. Warm oil leaks more past internal clearances, so volumetric efficiency falls. Both effects push the electrical input away from the clean theoretical calculation.
Yes, up to a point. A larger cylinder bore produces the same force at lower pressure, which cuts power if the flow stays the same, but it also needs more flow to keep the same speed. Unloading valves, two-stage pumps and accumulator-assisted circuits can all cut the average power demand during idle portions of the cycle.
For planning purposes, 0.85 overall is a reasonable middle figure for a gear pump power pack between 100 and 200 bar. If you are doing a final design, ask for volumetric and mechanical efficiency separately at the pressure and speed you actually intend to run.
Hydraulic pump power is pressure times flow divided by 600, and that number is the starting point rather than the answer. Divide it by an honest efficiency figure, check the peak against a stall or relief condition, confirm the duty cycle so the heat has somewhere to go, and then choose a motor or battery from the resulting electrical input. Do that and the power unit you receive will match the machine you designed instead of the test bench it was proven on.
If you would like the calculation checked against a specific application, the hydraulic power unit range covers AC, DC and oil-immersed designs from small pallet truck packs to large lifting platform units, and each one is built around the pressure, flow and duty numbers supplied by the machine builder.